Types and principles of towel disinfection cabinets Can towel disinfection cabinets sterilize bowls?

1. Principle of towel disinfection cabinet

1. Principle of high temperature disinfection cabinet

High temperature disinfection is to heat the temperature To 100 ℃, and keep it for more than 15 minutes, so as to achieve the purpose of sterilization. This high-temperature sterilization mainly includes: bacteria, viruses and other microbial organisms. The high temperature disinfection cabinet generally adopts the far infrared heating method. The electric heating element heats the air or generates radiant heat. After the appliance is subjected to high temperature for a period of time, the bacteria, viruses and other microbial protein tissues on the surface are deformed and killed.

2. Principle of ultraviolet disinfection cabinet

Ultraviolet rays can only travel in a straight line, with low radiation energy and weak penetrating power, and can only kill directly irradiated Therefore, when disinfecting, try to expose the disinfected area to ultraviolet rays. Ultraviolet rays are short wavelengths with wavelengths outside the visible range. They are a kind of visible “blue light” produced according to the principle of radiology, and have no effect on disinfection. Ultraviolet rays can be divided into A, B, and C according to the wavelength range.

3. Principles of ozone disinfection cabinets

In fact, ozone disinfection cabinets use the strong oxidizing properties of ozone to kill viruses. Ozone is a blue-colored explosive gas at room temperature with a special odor. It is one of the strongest known oxidants and a spectrum fungicide. However, ozone leakage will endanger our health, and the allowable threshold value in the air at the job site is 0.2mg/m3. Therefore, the ozone type disinfection cabinet needs to maintain the concentration of ozone in the cabinet while ensuring that the ozone does not leak to ensure the disinfection effect.

4. Principle of electric heating type disinfection cabinet

For electric heating type disinfection cabinet, high temperature is used to play a sterilizing effect. High temperatures are lethal to bacteria. The protein in bacteria is denatured and solidified due to heat, the activity disappears, and the metabolism is blocked, resulting in death. The disinfection temperature of the electric heating type disinfection cabinet should be ≥ 100 ℃, and the disinfection time should be ≥ 15 minutes.

2. Classification of towel disinfection cabinets

1. Classification by material

Divided into glass Door towel disinfection cabinet, all stainless steel towel disinfection cabinet, stainless steel spray towel disinfection cabinet, towel cart.

The glass door towel disinfection cabinet has a fully transparent curved glass door, and the cleaning and insulation status of the towel in the cabinet is more clearly visible. The simple and clear panel operation makes it easy to operate.

The stainless steel spray towel disinfection cabinet is made of high-quality steel plate and sprayed on the surface, and the inner tank is made of stainless steel. It is equipped with a curved plastic door.

All stainless steel towel disinfection cabinet The cabinet is all stainless steel, with novel shape, beautiful and fashionable, hygienic and clean.

The super luxurious silk-screened flip glass door cover of the towel trolley is equipped with a slender, comfortable, smooth and smooth stainless steel handle, which is more luxurious and luxurious. The unique round window glass door is specially configured for mobile The blue towel can save more space when delivering towels. The mobile power plug is suitable for power plugging in various environments, which fundamentally solves the inconvenience of power plugging. The unique universal wheel and hand Push the handle for more convenient and flexible movement.

2. Classification by disinfection method

It can be divided into electric heating towel disinfection cabinet, electric steam towel disinfection cabinet, and hot and cold towel disinfection cabinet.

Electric heating towel disinfection cabinet:It adopts the principle of automatic electric heating temperature control, and is equipped with overheating protection device; it has a heat preservation and moisturizing device, and ultraviolet sterilization and disinfection function; just start the button, the electric heating The heating system automatically heats up; when the temperature in the cabinet reaches the set temperature, the program automatically enters the heat preservation state; when the temperature in the cabinet is lower than the set temperature, the electric heating system automatically heats up.

Electric steam towel disinfection cabinet: The automatic temperature control device can make the towel both clean and warm, without worrying about any damage and discoloration of your towel. Holds a lot of towels for steam sterilization and moisturizing at the same time.

Hot and cold towel disinfection cabinet: It adopts automatic temperature control and is equipped with overheating protection device. It has dual options of cooling and heating, which is more powerful. Just need to start the button, the electric heating or refrigeration system will be automatically turned on. When the temperature inside the cabinet reaches the set temperature, the program will automatically enter the heat preservation state. When the temperature inside the cabinet does not reach the set temperature, the system will work automatically.

3. How to use the towel disinfection cabinet

1. Place the electric towel disinfection cabinet on the table or confirm a stable and safe place before use .

2. Please reconfirm whether the power supply voltage used is the same as that specified in the instruction manual of the towel disinfection cabinet.

3. Insert the power plug of the electric towel disinfection cabinet into a safety socket with a reliable grounding system.

4. Put clean wet towels neatly on the sieve rack, then put them into the electric towel disinfection cabinet, and close the cabinet door.

5. Press the power switch, the red indicator light of the power is on, and the towel disinfection cabinet has entered the heating working state.

6. When the required temperature is reached, enter the heat preservation state according to the program. If the temperature is lower than the set temperature, the electric heating system will automatically heat up and work.

7. If the towel disinfection cabinet is finished working, just pop the power switch.

4. Precautions for the purchase of towel sterilizers

1. Check the power components of the towel sterilizers

The power switch button of the towel disinfection cabinet should be flexible and reliable, the response of power on and off is rapid, and the indicator light is on and off normally; the connection of the power cord is firm and not loose, the insulation layer is not damaged, and the connector is inserted and pulled properly. Whether the ground wire can be connected to the ground terminal.

2. Check the product quality manual of the towel sterilizer

Consumers should ask the seller for the product quality supervision and inspection by the state when purchasing the towel sterilizer The product quality inspection report issued by the department should also pay attention to whether the product has a health license issued by the health and epidemic prevention department, and the inspection report of the sterilization and disinfection effect.

3. See if the dynamic lock switch is installed.

Since the towel disinfection cabinet is sterilized by ozone, if the dynamic lock switch is not installed, it will not be completed. Disinfection and opening the towel disinfection cabinet will cause high-concentration ozone leakage, affecting the health of users.

4. Check whether the towel disinfection cabinet is well sealed

Insert a small piece of cardboard into the door gap of the towel disinfection cabinet to see if It can be inserted. If it can be inserted easily, it means that the sealing effect of the towel disinfection cabinet is not good. Consumers should not buy it.