How to repair the air conditioner fan

Common Troubleshooting of Air Conditioning Fans

One.Air Conditioning FansNo wind, little wind

1. See if the wind is inhaled. If there is wind on the back, it may be that the fan motor is connected incorrectly. You can adjust the contact wire of the motor to solve it, about 10~30 no. Wait until it can be done.

2. It may be that the shaft under the control panel is blocking the air outlet and is broken. Find a master or seal it yourself with glue.

3. The fan is bad and it is the motor itself. This is a little more troublesome, and the motor needs to be replaced.

Second, the air-conditioning fan cannot be cooled

1. Check whether the green ice curtain is on Wet, this phenomenon can also occur if it is tilted or not installed properly.

2. Check whether the water pump is working. If it does not pump water, first check if the line is broken. You can A. Check the integrity of the line to determine that there is a problem with the pump B. The line is disconnected and the connection line is disconnected.

3. For normal use, you can wet the ice curtain with ice water first and then install it, so that the wind effect will be better.

Three, the air-conditioning fan is leaking

1. Check the water tank to see if the water tank is damaged.

2. Check the water pump to see if the rubber tube on the water pump is damaged or the interface is not installed properly. You can replace or wrap the interface to solve the problem.

3. Another is that the sink bracket is broken, which causes the sink to be tilted and leaked. If this is crooked, you can use 502 to fix the bracket to see if it can be done. Generally speaking, it works, and it is good to compensate a little.

4. The ice curtain was not installed properly, and the water dripped from the hole in the sink and sputtered along the ice curtain to the back cover of the air conditioner fan, and accumulated water droplets dripped out. Correct installation can solve the problem.

5. There are many air-conditioning fans without water tanks, and the bottom shell is directly connected to the universal wheel, and many leaks are leaked at the bottom universal wheel. You can check whether the universal wheel interface is damaged, and it can be blocked with glue or ordinary waterproof tape.

6. The plug at the bottom is not installed properly, causing water leakage.

Fourth, the page does not turn

1. Check the page first, if it is caused by not being installed properly, just reinstall it. It is also possible that the page layout is stuck, which is less common. There are also damaged blades that cannot swing, and the direction of the air outlet can be adjusted manually.

2. If the line that controls the page swing motor is lost or the page swing motor is broken, you can find a master to take a look at it. The lid inspection is judged by the internal drawing.

5. The air conditioner fan cannot be heated

1. First, check if the body is hot or not. If the body is hot, it means that the heating plate is working , is normal, the explanation is that it may be because the weather is hot, the feeling of hot air is not very good, and it will be fine when the weather is colder.

2. The button of the heating function of the control panel is broken, you can open the back cover to view the control panel.

3. You can open the back cover to check whether the clip on the side control gear is broken. Or the screw is too loose.

4. If it is caused by the problem of its own internal circuit, it can only be seen by the maintenance master.

Six.Air conditioner fanloud

1. Because the air outlet itself is relatively large , There is also a tuyere inside, and sound will be generated when the wind wheel rotates, this is a normal phenomenon.

2. Check whether the wind wheel sucks in debris such as hair, open the back cover and clean it up.

3. Check whether the wind wheel shaft is broken. If it is not broken, you need to add lubricating oil to solve the problem.