[Winter heating problems] Common problems of home heating system are dealt with in this winter to provide heating in time without fear of cold!

The weather is cold, and there are many heating measures in the south in winter. All kinds of fancy heating methods make the southerners who are shivering in the low temperature find hope for a safe winter. We northerners are different. Every household has heating, central heating, household heating, floor heating, wall-hung boilers and other heating systems have started to operate. However, some problems will inevitably occur after a long time of home heating. Water leakage, seepage, no heat, burst, etc. are all common faults. If not handled properly, it will affect family life. Frequently asked questions can also help you know how to deal with them in a crisis. What are the common problems of home heating system and how to deal with them? This winter, I will bring warmth to everyone in time.

What are the central heating methods in winter heating

Advantages: Improve energy utilization, save energy, improve heat quality, and improve the environment

Disadvantages: The heating comfort is poor, it takes up space, and the heating pipe network facilities require long-term maintenance

Price: Cheaper

Principle: The boiler heats the water, and then sends it to each household through pipes

Distributed heating

Advantages: The construction is flexible, easy to centralize management, easy to maintain, easy to overcome hydraulic pressure Maladjustment

Disadvantages:Severe waste, unguaranteed heating, high noise and nuisance

Price: High

Principle:A system that uses a gas water heater (gas furnace) with sufficient power to provide heating and domestic hot water for households

Geothermal floor heating

Advantages:

strong>Comfort, sanitation, health care, space saving, beautifying room, high efficiency and energy saving, good stability, strong adaptability

Disadvantages: Cumbersome installation, large thermal inertia, complicated maintenance

Price:High

Principle: The whole ground is used as a radiator, and the heat medium in the floor radiation layer is used to heat evenly The whole floor

wall-hung boiler

Advantages: The heating is flexible and convenient, heating up quickly, heating time and room temperature can be adjusted

Disadvantages: Cumbersome maintenance, noisy, high cost

Price: High

Principle: After premixing with air, it is ignited and burned, and the heat medium water is passed through the heat exchange system, and then the air is heated through the heat dissipation terminal for heating or heating

Air energy heat pump

Advantages: Scope of application Wide, energy-saving effect, environmental protection, safety, high comfort

Disadvantages: The purchase cost is relatively high, the installation and maintenance are more troublesome

Price : High

Principle: The unit uses a small amount of electricity to drive the compressor to work, absorb the low-temperature heat in the air, and pass it through the condenser or evaporator. hot Exchange, heat the cold water

Central heating problem Pipeline problem

Pipe leakage: For a long time, sand holes will cause water leakage. If it is not serious, you can use sealant and raw material tape to wrap it tightly. Change PPP pipe

Pipe dripping: The valve is not fully opened or the opening is too small, or the water flow is not washed by debris, adjust it manually, and turn the return water fully open to adjust Water supply

There is a lot of scale: If the radiator is used for a long time, scale will inevitably appear inside the pipeline. Protect the entire system

Pipe air: Check that the pipe valve is open or fully open. The exhaust valve of the user’s home on the top floor is opened to remove the air in the pipes

radiator problem

Half hot and half not hot: There is too much gas in the radiator, open the vent The valve releases the gas; the pipeline is blocked, please professional maintenance personnel to check and remove the pollutants.

Hot up and cool down: The valve of the water separator is not opened; the temperature control valve is not Turn it on and turn it counterclockwise to the end; it may also be poisoned by stolen goods, the inlet water pipe is reversed, etc.

The deflation needle is broken: Immediately use a thick towel, rag and other items Block or entangle it to reduce water flow

Low room temperature: If the number of pieces is small, you can add 1-2 pieces. If the floor is high or low, you need more , improve the sealing degree of the room

Overheating:Adjust the temperature control valve, lower the temperature slightly, the temperature will slowly drop after half a day, use a large humidifier, appropriate Open windows for ventilation

Other problems

Burst and leak of radiator: When the radiator bursts and leaks, immediately close the door valve, and then ask a professional to repair it

Occupy space and want to move: It is recommended not to move the radiator casually. If you really want to move, you can find a professional company to redesign the pipes.

Water leakage in heating facilities:The water flow is not If it is too large, you can gently wrap the pipe with a towel or a rag, and ask the professionals of the heating company to repair it.

The insulation material of the heating pipeline falls off: Once you find it, you should immediately report to the heating company. The heating company should send someone to replace or repair it in time.

Household heating problem food

Advantages Improved comfort, high space utilization, controllable cost, controllable scope, easy installation

How to arrange pipes indoors, according to the same plane Each household in the location is equipped with a common water supply and return riser; if it is set outdoors, each population is equipped with a common water supply and return riser

How to do concealment is mainly indoor concealed installation, and there are many ways of concealment, such as Install decorative partitions on the outside, buried pipes in the wall, etc., but choose the pipes, pipe routing and construction methods

Frozen cracked parts of the hot water pipes are sawn off with tools, and then connected Install a new pipe

Contact the relevant departments of the gas company and the heating company in time for natural gas leakage, and cut off some natural gas heating equipment in time

Water heating problems

First use or long-term unused When the floor heating is used for the first time, the heating will be relatively slow, and the heat transfer of the pipes will be relatively long.

The water floor heating system is not turned on. Check whether it is not fully turned on, and whether the floor heating system is fully turned on

If the water temperature is not up to standard, check whether there is a problem with the heat source equipment unit used, or whether it can meet the hot water temperature demand

The pipeline pressure is not enough During the construction of floor heating, the pressure test of the pipeline will be carried out to observe whether the floor heating pipe is cracked On

If the pipes are not cleaned for a long time, the floor heating pipe will produce dirt, which will make the temperature in the floor heating pipe not rise, so the floor heating pipe needs to be cleaned

The filter is blocked Be careful that the filter is blocked by scale , during the inspection process, the entire system can be inspected again

The floor heating was not installed according to the construction specifications when the floor heating coil was constructed, resulting in the floor heating not hot and only re-construction

Water seepage If there is water leakage, close the heating valve in time, close the valve of the water separator to control the water leakage, and seek professional maintenance personnel for maintenance.

Common problems of wall-hung boilers are insufficient pressure

phenomenon: The water pump does not turn, the controller Alarm, the fault code is insufficient pressure

Cause: Lack of water in the pipe, switch failure, a lot of air in the system

Solution: Carry out water replenishment, check with a multimeter, if the pressure switch is not turned on, replace the switch, and exhaust the pipeline system

Water shortage in the pipeline

Symptoms: The water pump does not run, the fan does not run, The fault code is water shortage in the pipeline

Cause: The power cord of the water pump falls off, and it does not need to be locked for a long time

Solution: Multimeter detection Whether the output power is normal, whether the contact is good, replace the wire, replace the water pump

Fan air pressure failure

Symptoms: The fan does not run or runs slowly, Display fan air pressure fault code

Cause: The fan is stuck and burned out, the connector is in poor contact, the controller is faulty, and the capacitor is damaged

Solution : Check the fan, the circuit breaker is stuck, replace the fan, reconnect the connector, replace the controller, replace the capacitor

Ignition failure fault

phenomenon: The ignition is normal, but The ignition fails, and the ignition failure fault code is displayed

Cause: The ignition needle is damaged and loose, the gas valve supply is abnormal, the ignition current adjustment of the proportional valve is unreasonable, and the gas valve valve has foreign objects

Solution:Replace the ignition needle, replace the main controller, replace the gas valve, remove foreign objects in the valve, adjust the ignition current

Accidental flameout failure

Symptoms: The flame is turned off after ignition, and the main controller alarms and displays the fault code of unexpected flameout

Reason: The flame induction needle has carbon deposits, the connection line is not in good contact, and there is too much wind outside. Large, the controller is faulty, and the flue is not installed

Solution: Clean the carbon deposits on the flame induction needle, connect the connecting wire, change the direction of the suction and exhaust position, and replace it Controller

overheating fault

phenomenon:The wall-hung boiler is off, the main controller alarms, and the overheating and dry burning fault code is displayed

reason:The distributor is closed, the heating pipeline is blocked, the overheating protection thermostat is bad, the controller is faulty, and the distributor is installed incorrectly

Solution: Open the heating distributor, dredge the pipeline, Replace the overheating protection thermostat, reassemble the distributor, clean the filter

Air source heat pump common problems compressor noise Looseness, low oil pressure, and excessive opening of thermal expansion valve

Solution: Check the pipeline and valve parts for tightening the compressor, replace the lubricating oil, and adjust the thermal expansion valve

Frost on the compressor surface

Cause: The thermal expansion valve temperature sensing bulb falls off, the refrigerant is insufficiently charged, the thermal expansion valve fails or is opened too much

Solution: Re-wrapping the temperature sensor bag, detecting leaks, filling leaks, charging refrigerant, adjusting, cleaning, and replacing the thermal expansion valve

The heating capacity of the unit is low

Causes: Insufficient refrigerant, poor insulation of water system water tank, heat exchange of main engine heat exchanger Poor effect, dirty and blocked fluorine system

Solution: System leak detection and refrigerant addition, strengthening water system water tank insulation, cleaning heat exchanger, cleaning fluorine system

unit No display, no display

Cause:Power failure, loose power cord, mainboard fuse blown, thermal overload protector burnt

Solution:

strong>Disconnect the power switch, check the power supply; check the unit power cord and tighten it; replace the fuse; check the compressor power cord

The compressor does not stop

Reason: Thermostat Wrong placement or failure, wrong sensor probe resistance or disconnected sensor wire

Solution: Replace or replace the thermostat; replace the sensor probe

p> The main unit does not work

Cause:Power failure, control panel, controller does not display

Solution: Check whether the mains voltage and current are normal , Check whether the power is turned on, check whether the transmission signal line is loose

Recommended reading 01 [Renovation pipes and wires] Home improvement pipes and wires Daquan decoration hydropower renovation wiring project

The water circuit can be regarded as the arterial network of the home, and the hydropower renovation is the entire decoration construction The first step, no matter what…

02 [Shopping for decoration pipes] What kind of pipes are good for home decoration? How to choose the floor heating pipe for decoration?

Pipe is a building material that must be used in water inlet and outlet and floor heating. At the same time, the quality of the pipe also determines the quality of the…

03 How many square meters are used for the decoration wire? How much to buy? Complete guide for decoration wire purchase

Wire is an indispensable material for users in the process of electricity use, and its quality is directly related to the use of thousands of households…

04 How to wire and wire well for home improvement water and electricity ? Specifications for installation and layout of water and electricity for decoration

The installation and wiring of water and electricity for home decoration is extremely important. Circuit wiring installation should pay attention to the wiring position, each area…

05 How to wire in commercial places? Integrated wiring scheme for office and commercial space decoration

The wiring of commercial places involves many aspects such as large area, multiple functions, long lines, etc., as well as some temporary…

06 The pre-buried water and electrical pipes for home installation standardize the home wiring Precautions for pre-buried pipes

Considering the water and electricity needs of various spaces in home life in the future, generally, water and electricity lines should be prepared before decoration…

07 Self-built house water and electricity materials list Water and electricity installation and wiring are complete Raiders

Most of the rural houses are self-built by farmers. Although self-built houses are not as unified and standardized as commercial houses, the water and electricity…

08 How troublesome is water and electricity for families living on the top/ground floor? How to deal with water and electricity problems in key floor spaces deal with? Home improvement plumbing decoration is no longer difficult!

How to deal with common problems in hydropower renovation? Water and electricity decoration is extremely important for home decoration, it is to ensure that people are…