How to exhaust the floor heating water separator How to use the floor heating water separator

First, how to exhaust the floor heating water separator

First of all, prepare the water basin and drainage pipe. Because when the floor heating water separator is deflated, water may also be released, and then everyone finds the floor heating water separator at home. Generally, the water inlet pipe is on the top, and the water outlet pipe is on the bottom.

Generally speaking, each water distribution pipe must be vented, so that the floor heating will work better. Close the main valve first, and the floor heating water separator will start to deflate from left to right. When keeping the small water valve of the first water distribution pipe still, move the second to fourth small floor heating water separators to the right. After twisting it 90 degrees, and then closing it all, this means that only the gas of the first floor heating water divider is put.

After the gas has been released, it is time to start the water release. First connect the prepared plastic tube to the air vent, and then twist the small screw on the air vent to the right, so that water will start to drain. Generally speaking, the water just released is very turbid, and the temperature of the water is relatively low, but after a few pots, the water will gradually become clear, and the temperature will gradually increase, you can use your hands distinctly felt. When the first water distribution pipe is finished, the small water valve can be closed, and then the second one can be put in, and the water will be discharged in sequence until all.

Second, the use of floor heating water divider skills

1. The water divider can control the water flow of each room or area by branch, such as: If any one of the rotary core valves on the water heater is half closed, the temperature of the room heated by this water circuit will decrease.

2. The manual exhaust valve on the water distributor, if the heating is not smooth and the air is blocked in winter, the user can use the exhaust device to manually exhaust the air in the floor heating pipeline. Make sure that the hot water circulates properly.

3. There is a filter on the front end of the water separator. During the heating period every year, the user regularly or irregularly removes the filter screen at the lower end of the filter, cleans it, and installs it to ensure the cleanliness of the water pipe. After heating, the pipe network should be flushed with clean water.

4. If you are away from home for a long time, the main valve of the water separator can be used to reduce the circulating water volume, and it must not be completely closed. If the room is not heated throughout the winter, the water in the pipe should be blown out.