The most reasonable number of ground heating water dividers The more the number of ground heating water dividers, the hotter

1. The most reasonable way of the floor heating water distributor

1. The floor heating water divider is divided into several ways, which mainly depends on the heat source used. If it is an ordinary house with an area of about 100 square meters, if you choose central heating, the 6-8 way of the floor heating water separator is the most suitable.

2. But if the wall-hung boilers are used for household heating, the requirements are different. The number of circuits may be slightly more, but the length of the single-circuit pipe will be reduced.

3. The number of paths of the floor heating water divider needs to be determined according to the size of the normal house area. For example, for a house of 50 square meters, it would be very wasteful to use the 6-8 road, because the 6-8 road is suitable for houses of more than 100 square meters.

4. There are 9 floor heating water dividers at most. A normal loop is calculated according to the area of the pipes. The floor heating pipes of one route are calculated according to the length of the pipes and the spacing of 20 cm. One square meter is laid. With a pipe of 4 or 7 meters, 15 square meters can be covered. If the room in the home is 100 square meters, then a 6-circuit water divider should be used. For some users who need to install radiators in the bathroom, they can add more A set of loops.

Second, is it hotter if there are more floor heating water dividers?

The first few roads of the floor heating water divider will be very hot, but it is not a water divider The more heaters, the hotter, because whether the floor heating is hot or not depends mainly on how many meters each circuit has at the time of design. If it is not hot, just add a circulating pump on the return water side, and then look at the main pipe. Is the water supply in front of the sub-collector very hot?

III. Precautions for installation of floor heating water separator

1. The installation of floor heating water separator should be before the heating pipe is laid, or it should be installed with the water meter, The valves are installed synchronously, and during the installation process, special fixings are required, and the fixings are installed on the wall. After installation, it is necessary to check whether it is firmly fixed, so as to prevent the floor heating water separator from falling off during use.

2. In the process of installing the floor heating water separator, the level of the water separator should be ensured, and the installation position of the floor heating water separator should be determined in advance. If it is a semi-cline, a water divider should be installed at a high place, or a water divider should be installed at the high place and the low place. If it is a duplex structure, it is necessary to install a water divider on the flat pipe corresponding to the upper and lower floors.

3. When installing the floor heating water distributor, special attention should be paid to the connection of the water supply pipe, and the pipe length of each circuit should be controlled to make the pipe length of each circuit more uniform, and the water distribution pipe should be installed. After completion, the heating location of each circuit should be indicated to facilitate future use and maintenance.